Airthings Resources - Articles, Research & News on Air Quality - Get it Here! (2024)

Global warming and environmental changes have increased public interest in air quality over the past few years. As the significance of the outdoor environment grows, people are also becoming aware of the impact healthy indoor air quality can have on their family, friends and colleagues both at work and at home. With this mounting interest in mind, Airthings has decided to delve deeper into the different indoor air sensors on the market. We shall thoroughly break down the components to our sensors, and explain why they are most effective. Helping you to make an informed choice.

We shall start withCarbon dioxidesensors. Carbon dioxide is commonly known asCO2, a greenhouse gas which is harmful in high doses. Years of research has gone into the effects of carbon dioxide on the planet. As the UK’s National Meteorological Office (Met office) warns, “Since the Industrial Revolution, atmospheric CO2has increased by over 40% to levels that are unprecedented in at least 800,000 years”. Not only is it bad for the environment, but when this ever-increasing rise of CO2
collects indoors, there can be negative consequences on the population’s health.

The effects of excess CO2:

Airthings Resources - Articles, Research & News on Air Quality - Get it Here! (1)

This ever-increasing rise is creating a drive for high-quality carbon dioxide sensors in the home and workplace.

Two options, two different results.

There are many types of CO2sensors on the market. The two most common types are NDIR and a method that works from a calculation.

NDIR sensor

Airthings devices use NDIR sensors. They continuously measure the amount of CO2gas molecules present in the air.

NDIR technology:

There is a compact NDIR sensor installed in every AirthingsWave Plusdevice.

It measures the amount of CO2gas molecules in the chamber, which samples air from the room it is placed in. A light shines on a sensor at the other end of the chamber. As the light passes through the chamber, only CO2is absorbed. The sensor then measures how much light has passed through the chamber, excluding the CO2molecules. This gives an extremely accurate result of exactly how much CO2is present in the air. It actively counts the molecules every five minutes to ensure the most up to date statistics are provided.

VOC sensor:

Alternatively, many volatile organic compound (VOC) sensors are often used to measure CO2. Through a complex formula, the results are calculated based on the presence of VOC’s in the air. This option is often preferred if a device does not have space or means to install a sensor that is specifically designed to measure CO2.

Chemical carbon dioxide sensors:

Chemical carbon dioxide sensors offer the benefit of low energy consumption and small size. However, according toresearch, their overall lifetime is much shorter in comparison to NDIR sensors.NASA’sGlenn Research Center has been working on a solution to this problem and has recently launched a new type of carbon dioxide sensor which improves their pre-existing chemical sensor technology.

NDIR vs VOC in action:

Airthings Resources - Articles, Research & News on Air Quality - Get it Here! (2)

Let us now use genuine readings fromAirthings HQto demonstrate some potential issues with using a VOC sensor to perform a calculation.

VOC sensors often do not control for all extraneous variables such as ventilation systems or room population.

The graph above shows theVOCand CO2levels at Airthings HQ. On November 3rd, the CO2levels decrease. This is a weekend, so even though the ventilation system is off, the CO2levels decrease because there is no one in the office expelling CO2through breathing.

If we were to draw co2 levels solely from the VOC readings, we would receive inaccurate results. Although the CO2levels decrease on November 3rd, the VOC levels actually rise. VOC’s are being emitted through the off-gassing process from products such as carpets and furniture. Usually, the ventilation system counteracts this rise, however, due to the weekend, the system was switched off.

On November 3rd, VOC and CO2levels acted very differently at Airthings HQ. Therefore if we were to calculate CO2levels based on VOC, the results would be incorrect.

Airthings Wave Plus CO2 Sensor specifications:

  • NDIR Sensor (Non-Dispersive Infra-Red)
  • Measurement range 400–5000 ppm
  • Non condensing 0 – 85%RH
  • Optimum Accuracy ±30ppm ±3% within 15 – 35°C or 59 – 95 degrees fahrenheit and 0 – 80%RH can be reached after multiple settling cycles on locations with natural indoor CO2 fluctuations

Subscribeto our newsletter below for the latest indoor air quality news and exclusive offers!

Airthings Resources - Articles, Research & News on Air Quality - Get it Here! (2024)
Top Articles
Latest Posts
Article information

Author: Margart Wisoky

Last Updated:

Views: 5866

Rating: 4.8 / 5 (58 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Margart Wisoky

Birthday: 1993-05-13

Address: 2113 Abernathy Knoll, New Tamerafurt, CT 66893-2169

Phone: +25815234346805

Job: Central Developer

Hobby: Machining, Pottery, Rafting, Cosplaying, Jogging, Taekwondo, Scouting

Introduction: My name is Margart Wisoky, I am a gorgeous, shiny, successful, beautiful, adventurous, excited, pleasant person who loves writing and wants to share my knowledge and understanding with you.