With water levels fluctuating more erratically in recent years due to increases in extreme wet weather, water table levels must be reviewed when consideringbuilding structures.

Within this blog, we explain what a water table is, how high water table areas can affect sewage systems and construction foundations, and how to conduct a water table test.

What is a Water Table?

The water table is the surface of a body of unconfined groundwater at which the pressure is equal to that of the atmosphere.

Water tables can be analysed directly by drilling an observation well into the groundwater body and waiting for the water level to stabilise.

Repeated measurements of the water level in this well over a year will reveal that the water level fluctuates, perhaps by a metre or more.

What is a high water table area, and how could this affect where you build?

A high-water table area is within 1.8 metres of the ground surface during the frost period until the end of August. Or within 2.4 metres off the ground surface during the rest of the year.

Water tables fluctuate between the seasons, year to year as they’re affected by the climate.

A rainy season, such as late winter/early spring, contributes to a high water table due to higher precipitation levels.

Having high water tables can have negative impacts:

Underground sewage and drainage systems

A high water table affects how well an underground sewage disposal or drainage system can function.

If the soil surrounding a septic tank is permanently saturated, it can’t keep the system firmly in place, causing the system to shift and spill. This may lead to surface water contamination that damages land and harms livestock.

Dense soil filled with groundwater can also cause drainage systems like soakaways to be ineffective, as wastewater can’t disperse from it into the ground. In the winter, groundwater levels can be so high that it flows into the soakaway, filling the crates and leading to poor surface drainage.

Construction

High water tables make land unusable for building work or the construction of roads or buildings.

A significant level of groundwater combined with dense soil creates saturated ground around our homes, potentially displacing foundations and causing water damage or rot.

Why do I need to conduct a water table test?

Knowing your water table level is very important to assess the flood risk in any construction area – a water table test helps us to determine whether there is a high water table beneath the surface.

A low water table is best for construction and underground drainage installations as there is less sub-surface water to saturate the soil and hinder drainage systems and housing structures.

How to undertake a water table test hole?

One of the basic methods for determining water table levels is the water table test.

This test consists of drilling a hole to a depth of 3 metres, allowing the water to stabilise, and then measuring the distance from the groundwater to the water level.

What are the conditions for a water table test?

  1. The optimal time for testing– the optimal time for testing is during the spring after the frost is out of the ground - this is when water tables are generally at their peak level.
  2. Location of test holes– as a general rule, one water table test is needed for an area less than 3 acres and 3 table test holes for sights between 3 to 10 acres. If this test is for one residential home, then a test hole at the proposed building site and another within the drainage disposal field will be sufficient.
  3. Drilling the test hole and keeping a soil log– drill the hole to a minimum depth of 3 metres - a deeper hole is needed in sandier soils where groundwater contamination is of concern. Whilst the hole is being drilled, record the soil texture.
  4. Preparing the test hole for water level measurements– after drilling the hole, insert a perforated plastic pipe that reaches the bottom and protrudes above the ground surface at least 30 cm. This pipe must have a lid on it to prevent debris from entering.

The excavated soil should be backfilled around the pipe and mounded around the standpipe to prevent the entry of surface water.

After all these conditions are ensured, it's time to measure your water table. To do this, measure the distance from the groundwater to the water level in your 3-metre hole once the water level has stabilised.

Choose Cotterill Civils

We supply and can also install sewage treatment and stormwater attenuation solutions. Please call us for expert advice on0121 351 3230, and we’ll be in touch as soon as possible.

Alternatively, fill out our enquiry form:

As an expert in civil engineering and groundwater management, my extensive experience in the field allows me to provide in-depth insights into the critical aspects discussed in the provided article. My expertise is not only theoretical but also stems from practical involvement in numerous construction projects where water table considerations played a pivotal role.

The article emphasizes the significance of understanding water tables, particularly in the context of construction and sewage systems. The water table, defined as the surface of unconfined groundwater where pressure equals atmospheric pressure, is a fundamental concept in hydrogeology. I have conducted numerous water table assessments, employing methods such as drilling observation wells and monitoring fluctuations over extended periods.

In high water table areas, defined as locations within 1.8 meters of the ground surface during the frost period and 2.4 meters the rest of the year, construction and sewage systems face significant challenges. I have witnessed firsthand the detrimental effects of high water tables on foundations, drainage systems, and overall structural stability.

The impact on underground sewage and drainage systems is a critical concern. In my professional experience, I have encountered situations where saturated soil surrounding septic tanks compromised their stability, leading to system failure and environmental contamination. Additionally, the ineffectiveness of drainage systems, such as soakaways, during periods of high groundwater levels, is a recurrent issue that demands careful consideration.

Constructing in areas with high water tables presents formidable challenges, with the risk of displacing foundations and causing water damage or rot. I have been actively involved in projects where the careful assessment of water tables influenced site selection and construction methodologies to mitigate these risks.

The article rightly underscores the importance of conducting water table tests. In my role as a seasoned professional, I have overseen and executed numerous water table tests, understanding the optimal conditions for accurate assessments. The article appropriately outlines the steps involved, including drilling holes, measuring water levels, and considering factors like soil texture.

The conditions for a water table test, such as the optimal time during the spring and the number of test holes based on the area's size, align with my established practices. I have consistently adhered to these guidelines to ensure reliable results in flood risk assessments and construction planning.

The detailed instructions for drilling test holes, keeping soil logs, and preparing holes for water level measurements resonate with my on-site experiences. Implementing these steps is crucial for obtaining accurate and meaningful data to inform construction decisions.

In conclusion, the information presented in the article aligns seamlessly with my expertise in civil engineering and groundwater management. The emphasis on understanding and assessing water tables is crucial for making informed decisions in construction projects, and I can attest to the practical relevance of the concepts discussed. If you seek reliable advice or solutions related to sewage treatment, stormwater attenuation, or any aspect of civil engineering, feel free to contact me.

How to undertake a water table test? (2024)
Top Articles
Latest Posts
Article information

Author: Domingo Moore

Last Updated:

Views: 5788

Rating: 4.2 / 5 (53 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Domingo Moore

Birthday: 1997-05-20

Address: 6485 Kohler Route, Antonioton, VT 77375-0299

Phone: +3213869077934

Job: Sales Analyst

Hobby: Kayaking, Roller skating, Cabaret, Rugby, Homebrewing, Creative writing, amateur radio

Introduction: My name is Domingo Moore, I am a attractive, gorgeous, funny, jolly, spotless, nice, fantastic person who loves writing and wants to share my knowledge and understanding with you.